We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Architecture & Planning/Investigation of Seismic Performance of Double-Angle Braces with Single Lacing under Two-Step Variable-Amplitude Cyclic Loading
PeriodicalsArchitecture & Planning

Investigation of Seismic Performance of Double-Angle Braces with Single Lacing under Two-Step Variable-Amplitude Cyclic Loading

Checking your access to this record.

Abstract & Overview

Aceh Province, which is located in an earthquake-prone area, requires an earthquake-resistant structure, i.e., a Concentrically Braced Frame System (CBFs). The CBFs have brace elements installed diagonally on the structure, and it reduces horizontal displacement in the structure due to the earthquake. This study implemented several Two-Step Variable Amplitude (TSVA) loading histories, consisting of two cyclic uniform load blocks with low and high amplitudes, which represent a simplification of earthquake loads due to amplitude changes. The test was conducted by installing the CBF brace in the loading frame and applying the TSVA parallelly with long axis of the brace. The experimental study yielded that the CBF brace with the largest cyclic ranges exhibited the highest strength, stiffness, and dissipated energy. Furthermore, the braces tested under TSVA with less uniform repeated cycles exhibited better strength, stiffness, and dissipated energy, which corresponds to the smaller fatigue effect in the CBF brace, thereby enhancing their seismic capability. Observing the failure modes of the CBF brace indicated that all the specimens experienced flexural buckling due to the TSVA loading histories.

Cite this record

Arief Panjaitan, Yulia Hayati, Helfisa Ikram, Purwandy Hasibuan, Rudiansyah Putra, Surya Bermansyah, et al. (2026). Investigation of Seismic Performance of Double-Angle Braces with Single Lacing under Two-Step Variable-Amplitude Cyclic Loading. Disaster in Civil Engineering and Architecture, 3(2), 179–193. https://doi.org/10.70028/dcea.v3i2.129

Copy in another style

Panjaitan, A., Hayati, Y., Ikram, H., Hasibuan, P., Putra, R., Bermansyah, S., Fauzi, M., Haiqal, M., & Shimizu, M. (2026). Investigation of Seismic Performance of Double-Angle Braces with Single Lacing under Two-Step Variable-Amplitude Cyclic Loading. Disaster in Civil Engineering and Architecture, 3(2), 179–193. https://doi.org/10.70028/dcea.v3i2.129
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.