We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Upper extremity deep venous thrombosis and stenosis after implantation of pacemakers and defibrillators; A prospective study
PeriodicalsMedical Sciences

Upper extremity deep venous thrombosis and stenosis after implantation of pacemakers and defibrillators; A prospective study

Checking your access to this record.

Abstract & Overview

BACKGROUND: Obstruction of the access vein following cardiac pacemaker and defibrillator implantation is a common complication. However, the exact incidence and contributing risk factors are unknown. The aim of this study is to determine the incidence and analyze the contribution of each risk factor. METHODS: 57 consecutive patients candidate for their first transvenous pacemaker, implantable cardioverter-defibrillator (ICD), or cardiac resynchronization therapy device implantation were enrolled. After implantation, venography of the ipsilateral peripheral arm was performed. Patients underwent their second venography after the follow-up period of 3 to 6 months. RESULTS: 42 patients (13 females, mean age 59.71 ± 12.33) completed the study. The followup venography showed significant venous obstruction (more than 50%) in 9 (21%) patients, but in none of the individuals, venography revealed total occlusion of the veins. Patients with obstruction had more leads in their veins (2.56 ± 0.53 vs 1.58 ± 0.71, P = 0.001). Venous obstruction was significantly more prevalent in patients with implanted cardiac resynchronization therapy device compared with an ICD or pacemaker (p = 0. 01). Age, gender, diabetes mellitus, hypertension, ischemic heart disease and antiplatelet consumption did not reveal any other contribution to the risk of thrombosis. In multivariate analysis, total lead number was a positive predictor for venous occlusion (P = 0.015, OR:19.2, and CI: 1.7-207.1). CONCLUSION: Venous obstruction is relatively frequent after pacemaker or ICD implantation. This study also shows that pacemaker and ICD leads have a similar risk for lead-related venous obstruction. However, patients with multiple leads are associated with an increased risk.

Cite this record

Morteza Safi, Mohammad Ali Akbarzadeh, Azadeh Azinfar, Mohammad Hasan Namazi, Isa Khaheshi (2017). Upper extremity deep venous thrombosis and stenosis after implantation of pacemakers and defibrillators; A prospective study. Romanian Journal of Internal Medicine, 55(3), 139–144. https://doi.org/10.1515/rjim-2017-0018

Copy in another style

Safi, M., Akbarzadeh, M. A., Azinfar, A., Namazi, M. H., & Khaheshi, I. (2017). Upper extremity deep venous thrombosis and stenosis after implantation of pacemakers and defibrillators; A prospective study. Romanian Journal of Internal Medicine, 55(3), 139–144. https://doi.org/10.1515/rjim-2017-0018
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.