We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Biomedical Engineering/A Study on the Estimation of Continuous Blood Pressure using PIT and Biometric Parameters
PeriodicalsBiomedical Engineering

A Study on the Estimation of Continuous Blood Pressure using PIT and Biometric Parameters

Checking your access to this record.

Abstract & Overview

In this paper, we propose a subject-independent regression model to estimate systolic blood pressures (SBP) conveniently and continuously. There have been several researches on estimating SBP with pulse transit time (PTT) and they showed promising results. However, previous studies used only PTT as the estimation parameter, and their models were generated with just one person's PTT data which is not applicable to estimating other person's SBP. Therefore, we collected several additional biometric parameters with 202 healthy subjects. After statistical analysis of measured biometric parameters with SBP, we chose final estimating parameters including PTT to generate a multiple linear regression model for estimating SBP. Comparing the results of our study with approvable standards of automated sphygmomanometers developed by Association for the Advancement of Medical Instrumentation and approved by American National Standards Institute (ANSI/AAMI) indicates that our proposed method for continuously blood pressures monitoring gives an acceptable error.

Cite this record

Park Eunkyoung, Baek Hwan Cho, Park Sang-Hae, Jong-Youn Lee, Hwan‐Sik Hwang, Park Hun-Ki, et al. (2006). A Study on the Estimation of Continuous Blood Pressure using PIT and Biometric Parameters. Journal of Biomedical Engineering Research, 27(1), 1–5. https://library.shubhaarti.com/content/f9242475-dbac-493c-989a-505059f4d1f8

Copy in another style

Eunkyoung, P., Cho, B. H., Sang-Hae, P., Lee, J., Hwang, H., Hun-Ki, P., Jong-Shill, L., Kim, I., & Sun-I, K. (2006). A Study on the Estimation of Continuous Blood Pressure using PIT and Biometric Parameters. Journal of Biomedical Engineering Research, 27(1), 1–5. https://library.shubhaarti.com/content/f9242475-dbac-493c-989a-505059f4d1f8
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.