Home/e-Resources/Biotechnology/A point-of-care assay for alpha-1-acid glycoprotein as a diagnostic tool for rapid, mobile-based determination of inflammation
PeriodicalsBiotechnology

A point-of-care assay for alpha-1-acid glycoprotein as a diagnostic tool for rapid, mobile-based determination of inflammation

Checking your access to this record.

Abstract & Overview

Inflammation is a key component of immune response to infections and pathogenesis of metabolic and cardiovascular diseases. Inflammatory biomarkers, including alpha-1-acid glycoprotein (AGP), are considered prognostic tools for predicting risk, monitoring response to therapy, and adjusting nutritional biomarkers for accurate interpretation. Serum is considered a primary source of biomarkers; urine and saliva are increasingly being explored and utilized as rapidly accessible, noninvasive biofluids requiring minimal sample processing and posing fewer biohazard risks. A lateral flow immunoassay was developed for an established mobile-based platform to quantify AGP in human serum, urine, and saliva. Assay performance was assessed with purified AGP in buffer, diluted human serum samples (n = 16) banked from a trial in people living with HIV, and saliva and urine (n = 15 each) from healthy participants. Reference methods were conventional clinical chemistry analyzer or commercial ELISA. Bootstrap analysis was used to train and validate sample calibration. The correlation between the assay and reference method for serum was 0.97 (P < 0.001). Mean (95% CI) best fit line slope was 1.0 (0.88, 1.15) and intercept was −0.003 (−0.08, 0.09). The correlation for urine was 0.93, and for saliva was 0.97 (both P < 0.001). The median CV for the LFIA for AGP in buffer was 13.2% and for all samples was 28.7%. The performance of the assay indicated potential use as a rapid, low sample volume input, and easy method to quantify AGP that can be licensed and adopted by commercial manufacturers for regulatory approvals and production. This has future applications for determining inflammatory status either alone or in conjunction with other inflammatory proteins such as C-reactive protein for prognostic, monitoring, or nutritional status applications, including large-scale country level surveys conducted by the DHS and those recommended by the WHO.

Cite this record

Bryan M Gannon, Marshall Jay Glesby, Julia Leigh Finkelstein, Tony D. S. Raj, David Erickson, Saurabh Mehta (2019). A point-of-care assay for alpha-1-acid glycoprotein as a diagnostic tool for rapid, mobile-based determination of inflammation. Current Research in Biotechnology, 1, 41–48. https://doi.org/10.1016/j.crbiot.2019.09.002

Copy in another style

Gannon, B. M., Glesby, M. J., Finkelstein, J. L., Raj, T. D. S., Erickson, D., & Mehta, S. (2019). A point-of-care assay for alpha-1-acid glycoprotein as a diagnostic tool for rapid, mobile-based determination of inflammation. Current Research in Biotechnology, 1, 41–48. https://doi.org/10.1016/j.crbiot.2019.09.002
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.