We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Chemical Engineering/Effect of Perforated Inclination and Height of Sill on Maximum Scour Depth and Energy Losses Downstream a Sluice Gate
PeriodicalsChemical Engineering

Effect of Perforated Inclination and Height of Sill on Maximum Scour Depth and Energy Losses Downstream a Sluice Gate

Checking your access to this record.

Abstract & Overview

Screens have proven to be an effective choice for decreasing scour downstream of small hydraulic structures. This paper studies experimentally the performance of an inclined perforated sill with a fixed porosity of 41.1% and varied height. Six different relative heights (from 0.34 to 2.25) and inclination angles of screens (30 ˚, 60 ˚, 90 ˚, 120 ˚, and 150) were tested under different flow conditions. The presence of a screen in the stilling basin reduced the maximum scour depth until the relative screen height was less than two compared to the no-screen case. A relative screen height greater than two increases the maximum scour depth. The best relative height of the screen is found to be approximately unity from the scour point of view. while the relative energy loss increases positively with the relative screen heights. Moreover, the vertical angles provide the best conditions for scour and energy dissipation. Finally, an empirical equation was developed to predict the maximum scour depth. A good agreement was found between the results of the predicted equation and the experimental results, with a mean relative error of about 6%.

Cite this record

Elsayed mohamed Elshahat, Samar Hassan, Gamal M. Abdel-Aal, Eslam Eltohamy (2024). Effect of Perforated Inclination and Height of Sill on Maximum Scour Depth and Energy Losses Downstream a Sluice Gate. The Egyptian International Journal of Engineering Sciences and Technology, 47(1), 25–32. https://doi.org/10.21608/eijest.2023.244843.1249

Copy in another style

Elshahat, E. M., Hassan, S., Abdel-Aal, G. M., & Eltohamy, E. (2024). Effect of Perforated Inclination and Height of Sill on Maximum Scour Depth and Energy Losses Downstream a Sluice Gate. The Egyptian International Journal of Engineering Sciences and Technology, 47(1), 25–32. https://doi.org/10.21608/eijest.2023.244843.1249
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.