Abstract & Overview
Low temperature double glow plasma chromizing process of T8 steel was studied. The microstructure and the phase structure of chromized layer was analyzed. The depth of chromized layer and the distribution of microhardness and chromium concentration were measured. Bonding force between the layer and base was tested by scratching. The results showed that a good chromized layer could be also gained in T8 steel by low temperature double glow plasma chromizing process. The layer consisted of sediment layer, carbide layer and solid solution layer.