We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Materials Science/Tethering hydrophilic macromolecules onto inorganic nanoparticles via RAFT toward biocompatible polyethersulfone membrane
PeriodicalsMaterials Science

Tethering hydrophilic macromolecules onto inorganic nanoparticles via RAFT toward biocompatible polyethersulfone membrane

Checking your access to this record.

Abstract & Overview

Polyethersulfone (PES) polymers are useful for a variety of membranes' bio-related applications. However, due to its failure to satisfy certain performance and biocompatibility standards, PES requires further surface modification. Herein, we report a facile and flexible method of PES membrane modification by combining the synthesis of silicon oxide nanoparticles grafted with polyvinylpyrrolidone (PVP) as hydrophilic macromolecules via reversible addition fragmentation chain-transfer polymerization (RAFT) and aminated polyethersulfone. The blending of polyethersulfone-modified membranes with SiO2@PVP and aminated polyethersulfone results in a robust, hydrophilic, and biocompatible surface. This research work uniquely uses this strategy to stabilize the existence of the hydrophilic modifiers (SiO2@PVP and aminated polyethersulfone) within the membrane matrix. Fourier-transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), and scanning electron microscopy (SEM) are used to analyze the prepared polymer brush and the modified membranes. The modified membranes demonstrate high pure water flux at 345 ​L ​m−2 ​h−1 and bovine serum albumin (BSA) rejection at 98 ​%. The prepared membranes also show favorable hydrophilicity with a contact angle of 46.8° compared with pristine polyethersulfone at 79°. Furthermore, the modified membranes demonstrate an acceptable degree of blood biocompatibility according to partial thromboplastin time (APTT), prothrombin time (PT), thrombin time (TT), and fibrinogen (FIB) concentration analysis. Based on inductively coupled plasma optical emission spectroscopy (ICP-OES), the silicon nanoparticle leaching in permeate is in a safe range. Accordingly, the modified polyethersulfone membrane is safe and suitable for hemodialysis and bio-related applications.

Cite this record

Mohammed Kamal Hadi, Liru Su, Yuan Li, Abdalazeez Ismail, Sambasivam Sangaraju, Fen Ran (2023). Tethering hydrophilic macromolecules onto inorganic nanoparticles via RAFT toward biocompatible polyethersulfone membrane. Advanced Membranes, 3, 100074–100074. https://doi.org/10.1016/j.advmem.2023.100074

Copy in another style

Hadi, M. K., Su, L., Li, Y., Ismail, A., Sangaraju, S., & Ran, F. (2023). Tethering hydrophilic macromolecules onto inorganic nanoparticles via RAFT toward biocompatible polyethersulfone membrane. Advanced Membranes, 3, 100074–100074. https://doi.org/10.1016/j.advmem.2023.100074
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.