Abstract & Overview
A simple, precise, accurate, robust, and specific stability-indicating HPTLC method was developed and validated for the estimation of Naltrexone hydrochloride (NTX) in bulk and tablet dosage form. The method was developed using pre-coated silica gel 60 F254 aluminum plates as a stationary phase, toluene: ethyl acetate: methanol, and triethylamine (TEA) in the ratio of 7.5:2:0.5:0.5, v/v/v/v as a mobile phase, and 208 nm as the detection wavelength. The linearity was found to be within the range of 1000–3000 ng/band, with a correlation coefficient (R2) of 0.9981. The detection limit and quantification limit for NTX were obtained to be 65.30 ng/band and 197.88 ng/band. The accuracy and reliability of the method were assessed by precision (inter-day %RSD 0.83–0.91% and intra-day %RSD 0.73–0.99% for NTX), % recoveries (99.67–100.47% for NTX), robustness, and specificity studies. A forced degradation study was carried out to determine NTX’s intrinsic stability. NTX was found to be more or less susceptible to degradation under all conditions. Still, the highest degradation was observed in photolytic conditions (UV radiation, short wavelength, 45 minutes). The proposed method can be utilized for routine analysis of NTX in pharmaceutical formulations in quality control laboratories.