Abstract & Overview
The purpose of the present study is to clarify experimentally the effects of surface tension on liquid film in upward annular flows in a vertical pipe of 19.2 mm i.d. and 5.4 m long. In the experiment, air was the test gas, while water and/or a dilute water solution of Polyoxyethylene-Lauryl-Ether (PLE for short) the test liquid. The surface tension of water was 72 dyne/cm and that of PLE 45 dyne/cm, but the viscosity and the density were nearly the same between these liquids. The liquid film behavior was studied using both the photograph and the time and spatial characteristics of peripheral-mean liquid holdup, which was detected with a series of 63 liquid holdup sensors each axially 15 mm apart in a constant current method. The data showed that the liquid film behavior strongly depends on the surface tension, i.e., the passing frequency of the large waves for PLE decreased remarkably; the wave height of the large waves for PLE became lower like small waves; the passing frequency of the small waves for PLE increased; and the small wave velocity for PLE became faster. Furthermore, the experimental data on the mean liquid film thickness and the gas-liquid interfacial shear stress were analyzed and discussed based on the result of the liquid film behavior.