We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Electronics & Telecommunication Engineering/The eddy-current and screen losses of a screened single-layer solenoid
PeriodicalsElectronics & Telecommunication Engineering

The eddy-current and screen losses of a screened single-layer solenoid

Checking your access to this record.

Abstract & Overview

The paper starts with an outline of Butterworth's method for the determination of the high-frequency resistance of an isolated single-layer solenoid. It points out that his method must tend to exaggerate the resistance, and accordingly a modification is suggested. By applying the modification, the high-frequency resistance of a particular coil is computed and it is shown that the losses are less than those which would be obtained using Butterworth's formulae. Comparison is made with Jackson's measurements, which show that Butterworth's formulae, in fact, tend to underestimate the resistance, and it is consequently noted that there must be a further underestimation by the method given in the paper.When the coil is surrounded by a concentric screening-can, not only are the losses in the coil altered, but further losses arise in the screening-can itself. Butterworth's method still applies to the former, and an expression is derived for the latter. This expression is compared with Bogle's empirical formula and is found to agree very well, provided that the coil is not too short.Finally there is a worked example where a particular screened coil is taken for which all the losses are calculated, and the effect of the screening-can on the Q-factor of the coil is determined.

Cite this record

F.M. Phillips (1950). The eddy-current and screen losses of a screened single-layer solenoid. Proceedings of the IEE - Part III Radio and Communication Engineering, 97(46), 77–87. https://doi.org/10.1049/pi-3.1950.0014

Copy in another style

Phillips, F. (1950). The eddy-current and screen losses of a screened single-layer solenoid. Proceedings of the IEE - Part III Radio and Communication Engineering, 97(46), 77–87. https://doi.org/10.1049/pi-3.1950.0014
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.