We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Physics/Identification of Differences in Body Composition Measures Using 3D-Derived Artificial Intelligence from Multiple CT Scans across the L3 Vertebra Compared to a Single Mid-Point L3 CT Scan
PeriodicalsPhysics

Identification of Differences in Body Composition Measures Using 3D-Derived Artificial Intelligence from Multiple CT Scans across the L3 Vertebra Compared to a Single Mid-Point L3 CT Scan

Checking your access to this record.

Abstract & Overview

Purpose. Body composition analysis in colorectal cancer (CRC) typically utilises a single 2D-abdominal axial CT slice taken at the mid-L3 level. The use of artificial intelligence (AI) allows for analysis of the entire L3 vertebra (non-mid-L3 and mid-L3). The goal of this study was to determine if the use of an AI approach offered any additional information on capturing body composition measures. Methods. A total of 2203 axial CT slices of the entire L3 level (4–46 slices were available per patient) were retrospectively collected from 203 CRC patients treated at Western Health, Melbourne (97 males; 47.8%). A pretrained artificial intelligence (AI) model was used to segment muscle, visceral adipose tissue (VAT), and subcutaneous adipose tissue (SAT) on these slices. The difference in body composition measures between mid-L3 and non-mid-L3 scans was compared for each patient, and for males and females separately. Results. Body composition measures derived from non-mid-L3 scans exhibited a median range of 0.85% to 6.28% (average percent difference) when compared to the use of a single mid-L3 scan. Significant variation in the VAT surface area ( p = 0.02) was observed in females compared to males, whereas male patients exhibited a greater variation in SAT surface area ( p < 0.001) and radiodensity ( p = 0.007). Conclusion. Significant differences in various body composition measures were observed when comparing non-mid-L3 slices to only the mid-L3 slice. Researchers should be aware that considering only the use of a single midpoint L3 CT scan slice will impact the estimate of body composition measurements.

Cite this record

Ke Cao, Josephine Yeung, Yasser Arafat, Matthew Yuan-Kun Wei, Justin M. C. Yeung, Paul Nigel Baird (2023). Identification of Differences in Body Composition Measures Using 3D-Derived Artificial Intelligence from Multiple CT Scans across the L3 Vertebra Compared to a Single Mid-Point L3 CT Scan. Radiology Research and Practice, 2023, 1–6. https://doi.org/10.1155/2023/1047314

Copy in another style

Cao, K., Yeung, J., Arafat, Y., Wei, M. Y., Yeung, J. M. C., & Baird, P. N. (2023). Identification of Differences in Body Composition Measures Using 3D-Derived Artificial Intelligence from Multiple CT Scans across the L3 Vertebra Compared to a Single Mid-Point L3 CT Scan. Radiology Research and Practice, 2023, 1–6. https://doi.org/10.1155/2023/1047314
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.