An Implantable Peripheral Nerve Interface System With Simultaneous Multisite Data Transmission via Galvanically Coupled Body-Channel Communication for Next-Generation Prosthetic Limbs

Checking your access to this record.

Abstract & Overview

This paper presents a neural implant system for prosthetic limbs that enables simultaneous multi-site data transmission via galvanically coupled body-channel communication (GC-BCC) for fine, low-latency control. Ultrasound and RF uplinks typically require multiple-access schemes to avoid collisions across implants. Capacitive BCC can support simultaneous links, but the small, motion-variant return-path capacitance reduces channel gain and undermines robustness. In contrast, GC-BCC forms a closed-loop current path for each transmitter.receiver pair via a dedicated termination, enabling simultaneous uplinks without multiple-access scheme. Implemented in 180-nm CMOS, the system integrates a 16-channel neural recording analog front end, a GC-BCC transceiver, and low-dropout regulators. Through 15-mm porcine tissue, the link sustains a 20-Mbps data rate with a bit-error rate below 1.3×105. Two GC-BCC transceivers operate simultaneously with 100-Ω termination with negligible crosstalk at ≥1.6-cm spacing. The measured energy efficiencies are 20.35 pJ/bit for the transmitter and 467.4 pJ/bit for the receiver.

Cite this record

Dong-Hwi Choi, Dongyoon Lee, Yunchul Chung, Hyun-Yeop Lee, Kim-Hoang Nguyen, Byeongseon Choi, et al. (2025). An Implantable Peripheral Nerve Interface System With Simultaneous Multisite Data Transmission via Galvanically Coupled Body-Channel Communication for Next-Generation Prosthetic Limbs. IEEE Open Journal of the Solid-State Circuits Society, 5, 324–334. https://doi.org/10.1109/ojsscs.2025.3642787

Copy in another style

Choi, D., Lee, D., Chung, Y., Lee, H., Nguyen, K., Choi, B., Yun, G., Ha, S., & Je, M. (2025). An Implantable Peripheral Nerve Interface System With Simultaneous Multisite Data Transmission via Galvanically Coupled Body-Channel Communication for Next-Generation Prosthetic Limbs. IEEE Open Journal of the Solid-State Circuits Society, 5, 324–334. https://doi.org/10.1109/ojsscs.2025.3642787
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.