We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Computer Science & Information Technology/ECG and NIBP Simulator in One Device Display on TFT Nextion
PeriodicalsComputer Science & Information Technology

ECG and NIBP Simulator in One Device Display on TFT Nextion

Checking your access to this record.

Abstract & Overview

Accurate monitoring of NIBP (Non-Invasive Blood Pressure) parameters using vital sign monitors is crucial for patient care. Therefore, calibration of vital sign monitors is essential to ensure their safety and reliability. A vital sign simulator was developed in this study, integrating ECG and NIBP parameters with a TFT Nextion display. The aim is to calibrate ECG and NIBP readings on vital sign monitors. The system utilized the Arduino Mega 2560 as the central controller and the MPX5050GP sensor for NIBP measurement and motor pump control. The NIBP parameters were measured at two settings: 60/30 and 80/50. The results showed a maximum systolic error of 3.5% and a diastolic error of 5.6% for the NIBP setting of 80/50. The largest standard deviation value of 2.05 was observed at the NIBP setting of 60/30. The highest uncertainty value of 0.5 was also found in the NIBP 60/30 setting. The obtained data indicated stable module readings within the acceptable threshold for vital sign monitor calibration. The developed vital sign simulator offers a reliable means of calibrating NIBP parameters, enabling accurate blood pressure measurements. Further research and refinement can be conducted to enhance the system's precision and expand its capabilities for calibration of additional vital sign parameters. By ensuring accurate calibration, healthcare professionals can rely on vital sign monitors for effective patient monitoring and diagnosis.

Cite this record

Cantika Melinda, I Dewa Gede Hari Wisana, Andjar Pudji, Triwiyanto Triwiyanto (2023). ECG and NIBP Simulator in One Device Display on TFT Nextion. Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics, 5(3), 151–157. https://doi.org/10.35882/ijeeemi.v5i3.179

Copy in another style

Melinda, C., Wisana, I. D. G. H., Pudji, A., & Triwiyanto, T. (2023). ECG and NIBP Simulator in One Device Display on TFT Nextion. Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics, 5(3), 151–157. https://doi.org/10.35882/ijeeemi.v5i3.179
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.