We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Automated Cytogenetic Biodosimetry at Population-Scale
PeriodicalsMedical Sciences

Automated Cytogenetic Biodosimetry at Population-Scale

Checking your access to this record.

Abstract & Overview

The dicentric chromosome (DC) assay accurately quantifies exposure to radiation; however, manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. This study evaluates the throughput of high-performance ADCI (ADCI-HT) to stratify exposures of populations in 15 simulated population scale radiation exposures. ADCI-HT streamlines dose estimation using a supercomputer by optimal hierarchical scheduling of DC detection for varying numbers of samples and metaphase cell images in parallel on multiple processors. We evaluated processing times and accuracy of estimated exposures across census-defined populations. Image processing of 1744 samples on 16,384 CPUs required 1 h 11 min 23 s and radiation dose estimation based on DC frequencies required 32 sec. Processing of 40,000 samples at 10 exposures from five laboratories required 25 h and met IAEA criteria (dose estimates were within 0.5 Gy; median = 0.07). Geostatistically interpolated radiation exposure contours of simulated nuclear incidents were defined by samples exposed to clinically relevant exposure levels (1 and 2 Gy). Analysis of all exposed individuals with ADCI-HT required 0.6–7.4 days, depending on the population density of the simulation.

Cite this record

Peter K. Rogan, R. Lu, E Mucaki, YanXin Li, B Shirley, Y. Li, et al. (2021). Automated Cytogenetic Biodosimetry at Population-Scale. Radiation, 1(2), 79–94. https://doi.org/10.3390/radiation1020008

Copy in another style

Rogan, P. K., Lu, R., Mucaki, E., Li, Y., Shirley, B., Li, Y., Wilkins, R., Norton, F., Sevriukova, O., & Pham, D. (2021). Automated Cytogenetic Biodosimetry at Population-Scale. Radiation, 1(2), 79–94. https://doi.org/10.3390/radiation1020008
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.