We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/A dosimetric analysis of 6MV versus 15MV photon energy plans for intensity modulated radiation therapy (IMRT) of carcinoma of cervix
PeriodicalsMedical Sciences

A dosimetric analysis of 6MV versus 15MV photon energy plans for intensity modulated radiation therapy (IMRT) of carcinoma of cervix

Checking your access to this record.

Abstract & Overview

BACKGROUND: Intensity modulated radiotherapy (IMRT) is being used to treat carcinoma of cervix (Ca Cx). Integral dose to normal tissue and increased leakage are the concern about IMRT. 6 MV photon beam is a good choice of energy for Ca Cx IMRT treatment. AIM: The objective of this study was to compare intensity modulated radiotherapy (IMRT) plans generated by 6 MV and 15 MV photon energies for carcinoma of cervix (Ca Cx) with regards to dosimetric parameters of planning target volume (PTV) and organs at risk (OAR), homogeneity index (HI), conformity index at 98% level (CI 98%), integral dose to normal tissue (NTID) and total number of monitor units (MUs). MATERIAL AND METHODS: A cohort of 16 patients was selected for this study. All patients were to receive a dose of 50 Gy in 25 fractions. IMRT plans were generated for both energies using same dose-volume constraints. RESULTS: Our results show a comparable coverage of planning target volume (PTV) for both energies. Volume of PTV receiving a prescription dose is 97.8 ± 0.5% and 98.8 ± 0.4% for the 6 MV and the 15 MV plans. Volume of PTV receiving a dose of 107% is 4.4 ± 7.8% and 16.1 ± 22.2%. Bladder and rectum mean doses for the 6 MV and the 15 MV photon plans were 39.8 ± 3.0 Gy and 40.0 ± 3.2 Gy, and 35.8 ± 3.1 Gy and 36.0 ± 3.1 Gy, respectively. Homogeneity index (HI) for both energies was 1.04. The conformity indices at 98% isodose (CI 98%) were 1.3 ± 0.1 and 1.4 ± 0.1 for 6 MV and 15 MV photon plans, respectively. CONCLUSIONS: We conclude that a 6 MV photon is a good choice for Ca Cx IMRT as it produces a highly conformal, homogeneous plan with superior target coverage and better OAR sparing.

Cite this record

Atul Tyagi, Sanjay S. Supe, sandeep sandeep, Man P. Singh (2010). A dosimetric analysis of 6MV versus 15MV photon energy plans for intensity modulated radiation therapy (IMRT) of carcinoma of cervix. Reports of Practical Oncology & Radiotherapy, 15(5), 125–131. https://doi.org/10.1016/j.rpor.2010.08.002

Copy in another style

Tyagi, A., Supe, S. S., sandeep, S., & Singh, M. P. (2010). A dosimetric analysis of 6MV versus 15MV photon energy plans for intensity modulated radiation therapy (IMRT) of carcinoma of cervix. Reports of Practical Oncology & Radiotherapy, 15(5), 125–131. https://doi.org/10.1016/j.rpor.2010.08.002
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.