Insulation defect detection in time ensures higher operational reliability of power system assets. Power transformers are the most critical unit of power systems both from economical and operational front. Hence it becomes necessary to have knowledge of the actual insulation condition of transformer to increase dependability of the system. The performance and ageing of the transformer insulation is mainly affected by Partial discharges (PD). Proper diagnosis in terms of amplitude and location of partial discharge in a power transformer enables us to predict well in advance, with much confidence, the defect in insulation system, which avoids large catastrophic failures. In this work a 20kVA, 230/50kV single phase core type transformer is used for evaluation of the transfer function-based partial discharge detection and location using modeling of the winding, using design data. The simulation of capturing on-line PD pulses across the bushing tap capacitor is done for various tap positions. Standard PD source model is used to inject PD pulse signal at 10 tap locations in the winding and corresponding response signatures are captured at the bushing tap end (across 1000pF). The equivalent high frequency model of the winding is derived from the design parameters using analytical calculations and simulations in packages such as MAGNET and ANSOFT. The test conditions are simulated using ORCAD-9 and the results are evaluated for location accuracy using design parameter based PD monitoring method. .

Cite this record

Santosh Kumar, Prakash Gupta, Athikkan Venkatasami, K. Udayakumar (2009). Design parameter based method of partial discharge detection and location in power transformers. Serbian Journal of Electrical Engineering, 6(2), 253–265. https://doi.org/10.2298/sjee0902253k

Copy in another style

Kumar, S., Gupta, P., Venkatasami, A., & Udayakumar, K. (2009). Design parameter based method of partial discharge detection and location in power transformers. Serbian Journal of Electrical Engineering, 6(2), 253–265. https://doi.org/10.2298/sjee0902253k
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.