We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Biomechanical Responses of Neonatal Brachial Plexus to Mechanical Stretch
PeriodicalsMedical Sciences

Biomechanical Responses of Neonatal Brachial Plexus to Mechanical Stretch

Checking your access to this record.

Abstract & Overview

This study investigated the biomechanical responses of neonatal piglet brachial plexus (BP) segments-root/trunk, chord, and nerve at two different rates, 0.01 mm/second (quasistatic) and 10 mm/second (dynamic)-and compared their response to another peripheral nerve (tibial). Comparisons of mechanical responses at two different rates reported a significantly higher maximum load, maximum stress, and Young's modulus (E) values when subjected to dynamic rate. Among various BP segments, maximum stress was significantly higher in the nerve segments, followed by chord and then the root/trunk segments except no differences between chord and root/trunk segments at quasistatic rate. E values exhibited similar behavior except no differences between the chord and root/trunk segments at both rates and no differences between chord and nerve segments at quasistatic rate. No differences were observed in the strain values. When compared with the tibial nerve, only mechanical properties of BP nerves were similar to the tibial nerve. Mechanical stresses and E values reported in BP root/trunk and chord segments were significantly lower than tibial nerve at both rates. When comparing the failure pattern, at quasistatic rate, necking was observed at maximum load, before a complete rupture occurred. At dynamic rate, partial rupture at maximum load, followed by a full rupture, was observed. Occurrence of the rate-dependent failure phenomenon was highest in the root/trunk segments followed by chord and nerve segments. Differences in the maximum stress, E values, and failure pattern of BP segments confirm variability in their anatomical structure and warrant future histological studies to better understand their stretch responses.

Cite this record

Anita Kumari Singh, Shania Shaji, Maria Delivoria‐Papadopoulos, Sriram Balasubramanian (2018). Biomechanical Responses of Neonatal Brachial Plexus to Mechanical Stretch. Journal of Brachial Plexus and Peripheral Nerve Injury, 13(01), e8–e14. https://doi.org/10.1055/s-0038-1669405

Copy in another style

Singh, A. K., Shaji, S., Delivoria‐Papadopoulos, M., & Balasubramanian, S. (2018). Biomechanical Responses of Neonatal Brachial Plexus to Mechanical Stretch. Journal of Brachial Plexus and Peripheral Nerve Injury, 13(01), e8–e14. https://doi.org/10.1055/s-0038-1669405
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.