Abstract & Overview
A sample size re-estimation (SSR) design is a flexible, adaptive design with the primary purpose of allowing sample size of a study to be reassessed in the mid-course of the study to ensure adequate power. In real world drug product, biologic, and device development, there may be large uncertainty in key factors that drive the sample size estimation for a confirmatory clinical trial. For example, early phase studies may have encouraging results but could be of shorter duration, or use a different endpoint than what is required for confirmatory phase clinical trials. The negative impact of high uncertainty at design stage for a confirmatory trial can be mitigated by an SSR design. Recent surveys have reported an encouraging upward trend in the use of SSR designs in clinical trials since the release of the draft guidance for adaptive design clinical trials for drugs and biologics by the U.S. Food and Drug Administration in 2010 (U.S. Food and Drug Administration (FDA) (February, 2010), Draft Guidance for Industry: Adaptive Design Clinical Trials for Drugs and Biologics). To support broad understanding and acceptance of SSR designs in confirmatory settings, especially unblinded SSR designs, we summarize statistical methods pertaining to SSR designs, including recent development in this field, and discuss design alternatives among blinded SSR, unblinded SSR, and conventional group sequential designs. To support appropriate implementation of SSR designs, we make recommendations on operational logistics for trial conduct based on accumulated experience in recent years, and provide points to consider for final data analysis and reporting for studies where the sample size has been increased following either a blinded or an unblinded SSR algorithm.