We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/Diagnostic Performance of ADC for Non-mass-like Breast Lesions on MR Imaging
PeriodicalsMedical Sciences

Diagnostic Performance of ADC for Non-mass-like Breast Lesions on MR Imaging

Checking your access to this record.

Abstract & Overview

We assessed the usefulness and limitations of utilizing apparent diffusion coefficient (ADC) values on diffusion-weighted imaging (DWI) for the differential diagnosis of benign and malignant non-mass-like breast lesions. We retrospectively reviewed 27 such lesions (16 malignant, 11 benign) detected on magnetic resonance (MR) imaging and analyzed the enhancing patterns of dynamic contrast-enhanced DCE-MRI (distribution and internal enhancement), kinetic curve patterns, and ADC values. All images were obtained with a 1.5-tesla MR unit, with patients supine. On DCE-MRI, malignant lesions tended to show either segmental or branching-ductal distribution, and when lesions with these patterns were considered malignant, sensitivity was 68.8%; specificity, 63.6%; positive predictive value (PPV), 73.3%; negative predictive value (NPV), 58.3%; and accuracy, 66.7%. Kinetic curve analysis did not reliably differentiate benign and malignant non-mass-like lesions. There was no significant difference between the mean ADC value of the malignant lesions, 0.968 × 10(-3) mm(2)/s at b=1000 s/mm(2), and that of benign lesions, 1.207 × 10(-3) mm(2)/s (P=0.109). Receiver operating characteristic (ROC) analysis revealed the most effective threshold of ADC value for differentiating tumors as 1.1 × 10(-3) mm(2)/s; values lower than this were observed more often in malignant than benign lesions (P=0.054). Us of this threshold yielded sensitivity of 68.8%; specificity, 72.7%; PPV, 78.6%; NPV, 61.5%; and accuracy, 70.4%. Combining the ADC value criteria with the analysis of DCE-MRI pattern increased sensitivity to 93.8%, negative predictive value (NPV) to 85.7%, and accuracy to 77.8% but decreased specificity to 54.5%. Use of ADC values does not adequately improve DCE-MRI performance for differential diagnosis of non-mass-like breast lesions, but adding the ADC value criteria to the DCE-MRI pattern analysis improves sensitivity, NPV, and accuracy.

Cite this record

Tsugumi Imamura, Ichiro Isomoto, Eijun Sueyoshi, Hiroshi Yano, Tatsuya Uga, Kuniko Abe, et al. (2010). Diagnostic Performance of ADC for Non-mass-like Breast Lesions on MR Imaging. Magnetic Resonance in Medical Sciences, 9(4), 217–225. https://doi.org/10.2463/mrms.9.217

Copy in another style

Imamura, T., Isomoto, I., Sueyoshi, E., Yano, H., Uga, T., Abe, K., Hayashi, T., Honda, S., Yamaguchi, T., & Uetani, M. (2010). Diagnostic Performance of ADC for Non-mass-like Breast Lesions on MR Imaging. Magnetic Resonance in Medical Sciences, 9(4), 217–225. https://doi.org/10.2463/mrms.9.217
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.