We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Electronics & Telecommunication Engineering/Impact of Power Grid Strength and PLL Parameters on Stability of Grid-Connected DFIG Wind Farm
PeriodicalsElectronics & Telecommunication Engineering

Impact of Power Grid Strength and PLL Parameters on Stability of Grid-Connected DFIG Wind Farm

Checking your access to this record.

Abstract & Overview

This paper investigates the impact of powergrid strength and phase-locked loop (PLL) parameters on small signal stability of grid-connected doubly fed induction generator (DFIG)based wind farm. Modal analysis of the grid-connected DFIG wind turbine under different operating conditions and various power grid strengths are investigated at first. Modal analysis results reveal that the DFIG connected to a weak grid may easily lose stability under the heavy-duty operating conditions due to PLL oscillation. The object of this paper is to identify the PLL oscillation mechanism as well as influence factors and propose a damping solution for this oscillation mode. A simplified linear system model of the grid-connected DFIG wind turbine is proposed for analyzing the PLL oscillation. Through the complex torque coefficients method and using this model, the oscillation mechanism and influence factors including the power grid strength and the PLL parameters are identified. To suppress this PLL oscillation, a mixed H2/H∞robust damping controller is proposed and designed for the DFIG. Electromagnetic transient simulation results of both singleDFIG system and multiply-DFIG system verify the correctness of the analysis results and effectiveness of the proposed damping controller.

Cite this record

Ju Liu, Wei Yao, Jinyu Wen, Jiakun Fang, Lin Jiang, Haibo He, et al. (2019). Impact of Power Grid Strength and PLL Parameters on Stability of Grid-Connected DFIG Wind Farm. IEEE Transactions on Sustainable Energy, 11(1), 545–557. https://doi.org/10.1109/tste.2019.2897596

Copy in another style

Liu, J., Yao, W., Wen, J., Fang, J., Jiang, L., He, H., & Cheng, S. (2019). Impact of Power Grid Strength and PLL Parameters on Stability of Grid-Connected DFIG Wind Farm. IEEE Transactions on Sustainable Energy, 11(1), 545–557. https://doi.org/10.1109/tste.2019.2897596
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.