Replacement of four individual, time-consuming and expensive ASTM standard methods for determination of Mo, As, Th and K in samples having uranium matrix with one new proficient method is considered. The main advantages of this method are overcoming the mentioned shortages and preserving the precision and accuracy of the analysis results for the desired technical specification of materials and nuclear industries. In the new method, the interfering uranium matrix was removed by extraction with a mixture of tri (2- ethylhexyl) phosphate (TEHP): n-Heptane. The elements were determined by inductively coupled plasma-optical emission spectrometry (ICP-OES) simultaneously. The effective parameters on the extraction including: pH, the remained uranium and temperature were studied. The dynamic range of calibration curve related to the element type was linear (R2>0.999) at 10-500 μg/g U. The method detection limits (MDL) of 0.51, 0.66, 1.1 and 0.55 μg/g U were obtained for Mo, As, Th and K, respectively. The obtained quantity of En for all elements was less than 0.26. The analytical precision and bias of current method at two different concentration levels were determined and compared with the available standard methods denoting an evidence of the method verification. The decreased analysis of time duration from ~24 hr to

Cite this record

J. Yazdani, H Rostamizadeh, M R Rezvanianzadeh, Safoora Rahimi, H Shahmir Barzoki, Rasol Sayyari, et al. (2014). SIMULTANEOUS DETERMINATION OF MO, AS, TH AND K IMPURITIES IN EXTRACTED URANIUM MATRIX, BY ICP-OES. Majallah-i ̒ulūm va funūn-i hastah/ī, 35(1), 41–48. https://library.shubhaarti.com/content/ff61a550-c9be-4128-a815-090c5c704cd4

Copy in another style

Yazdani, J., Rostamizadeh, H., Rezvanianzadeh, M. R., Rahimi, S., Barzoki, H. S., Sayyari, R., Aghahoseini, M., & Souri, A. (2014). SIMULTANEOUS DETERMINATION OF MO, AS, TH AND K IMPURITIES IN EXTRACTED URANIUM MATRIX, BY ICP-OES. Majallah-i ̒ulūm va funūn-i hastah/ī, 35(1), 41–48. https://library.shubhaarti.com/content/ff61a550-c9be-4128-a815-090c5c704cd4
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.