We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Medical Sciences/3D gamma analysis between treatment plans for nominally beam‐matched medical linear accelerators using PyMedPhys
PeriodicalsMedical Sciences

3D gamma analysis between treatment plans for nominally beam‐matched medical linear accelerators using PyMedPhys

Checking your access to this record.

Abstract & Overview

Beam‐matched linear accelerators (linacs) enable flexible patient scheduling and efficient treatment delivery in the event of unexpected machine downtime. The purpose of this study was to test the feasibility of 3D gamma index as an additional metric beyond standard measurement‐based comparisons for more efficient evaluation of treatment plans between linacs with nominally matched beam models to ensure safe patient transfer. Seventeen 3D conformal radiotherapy (3DCRT) plans and thirty‐six volumetric‐modulated radiation therapy (VMAT) plans for different disease sites were selected from the original linac. An in‐house script was used to automatically create new plans for the target linac and calculate dose using parameters of the original plans. 3D gamma analysis was performed to compare plan dose distributions between the target and original linacs using PyMedPhys. The 2%/2 mm gamma pass (γ≤1) rate was >99.99% for all 3DCRT plans. The median 1%/1 mm pass rate was 99.86% but two cases failed (< 90%). For VMAT plans, the median and minimum 2%/2 mm gamma pass rates were 99.43% and 93.81%. For 1%/1 mm, the median pass rate was 92.02% but ten cases failed. The results indicated using 3D gamma index can enhance the confidence and add an extra layer for safe patient transfer.

Cite this record

Fada Guan, William P. Donahue, Simon Biggs, Matthew Jennings, Emily Draeger, Huixiao Chen, et al. (2024). 3D gamma analysis between treatment plans for nominally beam‐matched medical linear accelerators using PyMedPhys. Precision Radiation Oncology, 8(4), 191–199. https://doi.org/10.1002/pro6.1247

Copy in another style

Guan, F., Donahue, W. P., Biggs, S., Jennings, M., Draeger, E., Chen, H., Wang, Y., Nguỹên, N. B., Carlson, D. J., & Chen, Z. (2024). 3D gamma analysis between treatment plans for nominally beam‐matched medical linear accelerators using PyMedPhys. Precision Radiation Oncology, 8(4), 191–199. https://doi.org/10.1002/pro6.1247
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.