We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Biotechnology/Diagnostic Accuracy of Apple Watch Electrocardiogram for Atrial Fibrillation
PeriodicalsBiotechnology

Diagnostic Accuracy of Apple Watch Electrocardiogram for Atrial Fibrillation

Checking your access to this record.

Abstract & Overview

Background Electrocardiography (ECG) is the gold standard for the diagnosis of atrial fibrillation (AF). Recently, smartwatches like the Apple Watch have emerged as a promising, user-friendly device for rapid detection and diagnosis of AF, but the reliability and diagnostic accuracy still remain controversial. Objectives The purpose of this study was to perform a systematic review and diagnostic test accuracy meta-analysis evaluating the diagnostic performance of the Apple Watch ECG in detecting AF. Methods The literature search was conducted on PubMed, Embase, and Cochrane Library through April 2024 for studies comparing the diagnostic accuracy of Apple Watch to standard 12-lead ECG. Statistical analysis was performed using R Software version 4.4.0 and OpenMeta[Analyst]. Pooled analyses of sensitivity, specificity, and area under the receiver operating characteristic curve were determined along with their 95% CIs. The quality of studies was analyzed using the QUADAS-2 tool. Results The meta-analysis included 11 studies comprising 4,241 participants. Their mean age was 62.56 ± 3.92 years, and 28% of the patients were females. The pooled sensitivity and specificity of the Apple Watch for detecting AF were 94.8% (95% CI: 91.7%-96.8%; I = 67%) and 95% (95% CI: 88.6%-97.8%; I = 88%), respectively. The area under the receiver operating characteristic curve was 0.96 (95% CI: 0.92-0.97). Conclusions The Apple Watch ECG carries high accuracy in detecting atrial fibrillation, providing a convenient diagnostic option for patients.

Cite this record

Sufyan Shahid, Minahil Iqbal, Humza Saeed, Sara Hira, Amna Batool, Salman Khalid, et al. (2025). Diagnostic Accuracy of Apple Watch Electrocardiogram for Atrial Fibrillation. JACC Advances, 4(2), 101538–101538. https://doi.org/10.1016/j.jacadv.2024.101538

Copy in another style

Shahid, S., Iqbal, M., Saeed, H., Hira, S., Batool, A., Khalid, S., & Tahirkheli, N. K. (2025). Diagnostic Accuracy of Apple Watch Electrocardiogram for Atrial Fibrillation. JACC Advances, 4(2), 101538–101538. https://doi.org/10.1016/j.jacadv.2024.101538
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.