We use a few cookies

Essential cookies keep the library working. With your permission, we'd also like to use analytics to see what's useful and improve the experience. Read our Privacy Policy or Cookie Policy.

Skip to main content
Home/e-Resources/Materials Science/Imaging and Simulation of Ruthenium Derivative Coating Microbeads at the Opaque Electrode with Electrogenerated Chemiluminescence
PeriodicalsMaterials Science

Imaging and Simulation of Ruthenium Derivative Coating Microbeads at the Opaque Electrode with Electrogenerated Chemiluminescence

Checking your access to this record.

Abstract & Overview

Electrogenerated chemiluminescence (ECL) imaging is gaining increasing attention in various fields because of its high sensitivity, low background, and good temporal and spatial resolution. However, ECL imaging of microsized objects at the opaque electrode via top-view configuration is challenged with the reactants’ diffusion and light propagation. Here, we imaged and numerically simulated ruthenium derivative coating polystyrene microbeads (Ru1-PS@MB) at the glassy carbon electrode (GCE) via top-view configuration by ECL imaging. The ruthenium derivative (bis(2,2′-bipyridine)-4′-methyl-4-carboxybipyridine-ruthenium N -succinimidyl ester-bis (hexafluorophosphate), Ru1), a typical ECL reagent, was covalently linked onto the surface of aminated PS@MBs via the amide reaction. “Strong emission in edge and weak emission in center” phenomena for fluorescence (FL) and ECL emissions were obtained from Ru1-PS@MB on GCE. Z-Stack imaging of the microsized Ru1-PS@MB luminescence was performed on GCE in the presence of tri- n -propylamine (TPA). It is found that the clear luminescence range of Ru1-PS@MB perpendicular to the electrode surface in ECL image is slightly smaller than that in the FL image. The bigger was the diameter of the microbeads (from 5 to 18 μm), the larger was the ECL luminescence range of Ru1-PS@MB perpendicular to the electrode surface (from 5 to 7 μm). Our findings, which are also supported by numerical simulation, provide insights into the ECL imaging of microsized objects at the electrode surface, which will raise promising ECL applications in bioassays and cell imaging at the microscale level.

Cite this record

Yanlong Feng, Wenshuai Zhou, Xiaofei Wang, Jian Zhang, Min Zou, Chengxiao Zhang, et al. (2023). Imaging and Simulation of Ruthenium Derivative Coating Microbeads at the Opaque Electrode with Electrogenerated Chemiluminescence. Chemical & Biomedical Imaging, 1(7), 648–658. https://doi.org/10.1021/cbmi.3c00042

Copy in another style

Feng, Y., Zhou, W., Wang, X., Zhang, J., Zou, M., Zhang, C., & Qi, H. (2023). Imaging and Simulation of Ruthenium Derivative Coating Microbeads at the Opaque Electrode with Electrogenerated Chemiluminescence. Chemical & Biomedical Imaging, 1(7), 648–658. https://doi.org/10.1021/cbmi.3c00042
Author names are used as deposited, so check their order before you submit.

Metadata is harvested from open-access indexes and can be incomplete. Check a citation against the published version before relying on it — see our open access & attribution policy.